Symptoms:
Cause: Actuator feed limit bore wear results in unregulated pressure at the EPC solenoid, 1-2, 3-4 shift solenoid and the 1-2, 3-4 shift signal circuit.
Correction: This wear-resistant sleeve and valve assembly allows the salvage of the case cover by re-establishing hydraulic integrity of the AFL circuit.
The OE actuator feed limit (AFL) valve routes regulated line pressure to the pressure control solenoid and the 1-2, 3-4 shift signal circuit in GM 4T65-E units. Wear at the AFL valve bore can cause low torque signal and/or low 1-2, 3-4 shift solenoid and shift signal circuit pressure, resulting in Code 1811, maximum adapt or long shift, TCC slippage and wrong gear starts. Bore wear also can cause poor EPC control, leading to high line pressure and TCC piston damage. The Sonnax AFL valve and sleeve kit restores hydraulic integrity to the AFL circuit.
Contents:
SONNAX Installation Instructions